AMALGAM  Series

WASTE WATER application and AQUACULTURE

25  .. 600 m3/hr    –    110  .. 2641 GPM

Initial UV DOSE @ 40.000 µWsec/cm2

Against Cryptosporidium, Giardia, Poliovirus, Adenovirus, VHS, ISA, IPN

LCD control logic UV³ series or EBM cabinet 

High efficiency amalgam UV-C lamp (14.000 hours lifespan)

High quality quartz sleeves

AISI 316 reactor

Sampling points

Horizontal or vertical installation

Standard  or certified Ö_NORM / DVGW  sensor optional

VERTICAL  Series

HORIZONTAL  Series

  • 25,0 m3/hr  -  110 GPM @ 40.000 µWsec/cm2
  • 1 x 200W UV-C amalgam lamps  (14.000 lifespan)
  • 1190 mm maximum dimension
  • 2" I/O connection
  • High efficiency electronic ballast
  • Standard Irradiance and Temperature sensor optional
  • Certified  Ö_NORM / DVGW sensor optional
  • 4-20mA output optional
  • Flanged connection  optional
  • EN 55022; EN 61000-3-2; EN 61000-4 compliance
  • UV AM25 with control cabinet LCD display UV³
  • 60,0 m3/hr  -  264 GPM @ 40.000 µWsec/cm2
  • 2 x 200W UV-C amalgam lamps  (14.000 lifespan)
  • 1190 mm maximum dimension
  • DN80 I/O connection
  • High efficiency electronic ballast
  • Standard Irradiance and Temperature sensor optional
  • Certified  Ö_NORM / DVGW sensor optional
  • 4-20mA output optional
  • Flanged connection  optional
  • EN 55022; EN 61000-3-2; EN 61000-4 compliance
  • UV AM60 with control cabinet LCD display UV³
  • 90,0 m3/hr  -  396 GPM @ 40.000 µWsec/cm2
  • 3 x 200W UV-C amalgam lamps  (14.000 lifespan)
  • 1190 mm maximum dimension
  • DN100 I/O connection
  • High efficiency electronic ballast
  • Standard Irradiance and Temperature sensor optional
  • Certified  Ö_NORM / DVGW sensor optional
  • 4-20mA output optional
  • Flanged connection  optional
  • EN 55022; EN 61000-3-2; EN 61000-4 conformità
  • UV AM90 with control cabinet LCD display UV³
  • 125,0 m3/hr  -  550 GPM @ 40.000 µWsec/cm2
  • 4 x 200W UV-C  amalgam lamps (14.000 lifespan)
  • 1190 mm maximum dimension
  • DN150  I/O connection
  • High efficiency electronic ballasts
  • Standard Irradiance and Temperature sensor optional
  • Certified  Ö_NORM / DVGW sensor optional
  • 4-20mA output optional
  • Flanged connection  optional
  • EN 55022; EN 61000-3-2; EN 61000-4 compliance
  • UV AM125 with control cabinet LCD display UV³
  • 100 m3/hr  -  440 GPM @ 40.000 µWsec/cm2
  • 2 x 400W UV-C amalgam lamps (14.000 lifespan)
  • 1800 mm maximum  dimension
  • DN100  I/O connection
  • Sampling point
  • Certified Ö_NORM / DVGW sensor optional
  • 4-20 mA output optional
  • EN 55022; EN 61000-3-2; EN 61000-4 compliance
  • UV HM100  with  EBM cabinet
  • 250 m3/hr  -  1100 GPM @ 40.000 µWsec/cm2
  • 4 x 400W UV-C amalgam lamps   (14.000 lifespan)
  • 1800 mm maximun dimension
  • DN200  I/O connection
  • Sampling point
  • Certified Ö_NORM / DVGW sensor optional
  • 4-20 mA output optional
  • EN 55022; EN 61000-3-2; EN 61000-4 compliance
  • UV HM250  with  EBM cabinet
  • 400 m3/hr  -  1761 GPM @ 40.000 µWsec/cm2
  • 6 x 400W UV-C amalgam lamps   (14.000 lifespan)
  • 1800 mm maximum dimension
  • DN250  I/O connection
  • Sampling point
  • Certified Ö_NORM / DVGW sensor optional
  • 4-20 mA output optional
  • EN 55022; EN 61000-3-2; EN 61000-4 compliance
  • UV HM400  with  EBM cabinet
  • 600 m3/hr  -  2642 GPM @ 40.000 µWsec/cm2
  • 8 x 400W UV-C amalgam lamps   (14.000 lifespan)
  • 1800 mm maximum dimension
  • DN250  I/O connection
  • Sampling point
  • Certified Ö_NORM / DVGW sensor optional
  • 4-20 mA output optional
  • EN 55022; EN 61000-3-2; EN 61000-4 compliance
  • UV HM600  with  EBM cabinet
  • High efficiency electronic ballast
  • Power supply 230 Vac (optional 115 Vac)
  • 2x8 character white/blue backlighted LCD display
  • Total and partial hour counter
  • Single lamp management
  • Stand by button
  • Remote ON/OFF operation
  • Flux switch input
  • Solenoid valve managing
  • Customizable relay output
  • Lamp change counter
  • Free contact alarm relay
  • Powered alarm relay
  • Audible alarm optional optional
  • Sensor management (Irradiance and Temperature)
  • 4-20 mA output optional optional

  • High efficiency electronic ballasts
  • Power supply  230 Vac  (115Vac optional)
  • 2x12 character white/blue backlighted LCD display
  • Total and partial hours counter
  • Single lamp management
  • "Stand by"  command
  • Change lamp counter
  • Free contact alarm relay
  • Output relay customizable  
  • Audible alarm  optional
  • 4-20mA output  optional Irradiance and Temperature  
  • Certified sensor managemenent  optional