MONO Series
DOMESTIC and POINT OF USE application
1,2 .. 5,0 m3/hr – 5,3 .. 22,00 GPM
Against: Cryptosporidium, Giardia, E.Coli and Fecal Coliform.
High efficiency low pressure UV-C lamp (9.000 hours lifespan)
High quality quarts sleeves
“A” basic electronic ballast plug or through cable
“D” smart LCD display logic UV³
AISI 304 standard reactor, AISI 316 optional
UV Irradiance and Temperature sensor optional
- 1,5 m3/hr - 6,60 GPM @ 30.000 µWsec/cm2
- 1,2 m3/hr - 5,28 GPM @ 40.000 µWsec/cm2
- 1 x 30W UV-C low pressure lamps
- 520 mm max size
- 3/4" I/O connection
- EN 55022 ; EN 61000-3-2 ; EN 61000-4 ; EN 61347-1/A1 ; EN 61195 ; 2014/30/EU ; 2014/35/EU compliance
- Irradiance and Temperature sensor optional
- UVC30A with ballast plug or through cable Download UVC30A
- UVC30D with control logic UV3 Download UVC30D
- 2,8 m3/hr - 12,30 GPM @ 30.000 µWsec/cm2
- 2,4 m3/hr - 10,60 GPM @ 40.000 µWsec/cm2
- 1 x 40W UV-C low pressure lamps
- 935 mm max size
- 1" I/O connection
- EN 55022 ; EN 61000-3-2 ; EN 61000-4 ; EN 61347-1/A1 ; EN 61195 ; 2014/30/EU ; 2014/35/EU compliance
- Irradiance and Temperature sensor optional
- UVC40A with ballast plug or through cable Download UVC40A
- UVC40D with control logic UV3 Download UVC40D
- 6,0 m3/hr - 26,4 GPM @ 30.000 µWsec/cm2
- 5,0 m3/hr - 22,0 GPM @ 40.000 µWsec/cm2
- 1 x 80W UV-C low pressure lamps
- 935 mm max size
- 1 ¼” I/O connection
- EN 55022 ; EN 61000-3-2 ; EN 61000-4 ; EN 61347-1/A1 ; EN 61195 ; 2014/30/EU ; 2014/35/EU compliance
- Irradiance and Temperature sensor optional
- UVC65D with control logic UV3 Download UVC65D
- Plug ballast
- Lamp cable1,5mt
- 90 to 240 Vac power suplly
- High efficiency lamp driver
- Green/red led for lamp monitoring
- EN 55022; EN 61000-3-2; EN 61000-4 compliance
- Through cable version available
- Audible beeper optional
- High efficiency electronic ballast
- 230 Vac power supply (115Vac optional)
- 2x8 character white/blue backlighted LCD display
- Total and partial hour counter
- Stand by button
- REMOTE ON/OFF operation
- Flux switch input
- Solenoid valve managing
- Customizable relay output
- Lamp change counter
- Free contact alarm relay
- Powered alarm relay
- Audible alarm optional
- Sensor management (Irradiance and Temperature)
- 4-20 mA output optional